+86-573-82571515

How To Solve The Problem Of Color Standard And Temperature Control In Mask Packaging Machine?

Sep 07, 2018

The wrapping paper used on the mask packaging machine is color-coded, and the general color standard is dark or contrasted with the color printed on the wrapping paper, so that the machine can accurately track the color standard. When the color code is too light, or the contrast is not obvious, or the color mark tracking is not turned on, the cut position will deviate from the color mark. At this time, the sensitivity should be adjusted to adjust the color mark tracker to the exact position. When the temperature gauge cannot control the temperature, the thermocouple may be damaged or the temperature control table may be damaged. At this time, the thermocouple and the temperature control table should be replaced.